The 220L Digital Flowmeter with flow rates from 5 mL/min to 500 mL/min, allows users to verify gas flow rates, in the field or in the lab, to an accuracy of ±1% percent for readings standardized for temperature and pressure and ±0.75% in volumetric flow.
Unlike thermal mass flow meters, the 220L positive displacement technology provides immediate indication of actual volumetric gas flow rate, accurately and independently of gas type. Integrated temperature and pressure sensors in the flow stream allow users to automatically standardize volumetric flow readings to standard conditions, for traceable verifications of mass flow devices.
A versatile, push-button flow meter, the 220L enables the user to accurately calibrate a variety of instruments while maintaining an ISO 17025-traceable audit trail.
Size |
5.5"H x 6"W x 3"D |
Weight |
29 oz. / 820 g |
Flow Ranges |
5 to 500 scc/min |
Accuracy |
At gas pressure of 760 mmHg, gas temperature of 25°C with standard temperature set to 0°C. |
Standardized |
±1.0% |
User-Selectable Measurement Units |
|
Volumetric Flow |
mL/min, L/min, cc/min, cf/min |
Standard Flow |
smL/min, sL/min, scc/min, scf/min |
Pressure |
mmHg, PSI, kPa |
Temperature |
ºC, ºF |
Approximate Time per Reading |
1-15 seconds |
Gas Compatibility |
Use with non-corrosive, non-condensing, non-combustible gases, less than 70% humidity |
Flow Modes |
Suction or Pressure |
Measurement Cell Style |
Integrated |
Temperature & Pressure Sensors |
In the flow stream |
Reading Styles |
Single (manual), Continuous or Burst, with averaging function user-selectable from 1 to 100 measurements |
AC Adapter/Charger |
12 DC, >250 ma, 2.5 mm, center positive |
Battery System |
6V rechargeable, sealed lead-acid, 6-8 hours typical operation |
Battery Operational Time |
3 hours backlight on, 8 hours backlight off |
Pressure & Suction Fittings |
¼” ID Swagelok® compression fittings |
Warranty |
Instrument: 1 year, Battery: 6 months |
Storage Temperature |
0-70 °C |
Ambient Humidity |
0-70% - non-condensing |
Operating Pressure |
(Absolute) 15 PSI |
Display |
Backlit graphical LCD |
Data Port |
Serial RS-232 (for use with Optimizer software) |
Data Cable |
1 meter (220L Data Port to PC Serial Port) |
Laboratory Accreditation |
Instruments are manufactured and calibrated by a company accredited to the ISO 17025, ANSI Z540, and NIST Handbook 150 standards. Traceability to the International System of Units (SI) and NIST is verified by accreditation to the ISO/IEC 17025 by NVLAP under Code 200661-0. |
Instrument Certification |
RoHS and CE Compliant |